Research Paper |
Title |
: |
Highly Selective Iodide–Membrane Electrode Based On
[CoL] SO4 |
Country |
: |
India |
Authors |
: |
Seema Sharma, K K Sharma |
|
: |
10.9790/5736-07125056 |
Abstract: A novel potentiometric membrane sensor has been developed and optimized based on 3,5,13,15-tetramethyl-4,14-diethyl-2,6,12,16,21,22-hexaazatricyclo [15.3. I 1-17 I 7-11] dicosa-1,(21),2,5,7,19,11(22),12,15,17,19-decaene Cobalt Sulphate ionophore in poly vinyl chloride matrix membrane (PVC) plasticized with dibutyl phthalate (DBP), for high selective determination of iodide ion. The sensor works well in a linear range: 1.0×10-2 – 1.0×10-6 M with a Nernstian slope of -58.6 ±0.4 mV/decade and its detection limit is 8.0×10-7 M. The sensor shows working range over the pH 3.0-9.5 and stable for a period of 2 months with response time <15 s. The selectivity coefficient values as determined by fixed interference method indicate a good selectivity for ions over a wide variety of other tested anions.
[1] N.N. Greenwood, A. Earnsltaw, Chem. Elem., 1984, 933.
[2] H.R. Pouretedal, M.H. Keshavarz, Talanta, 2004, 62, 223.
[3] Y. Yabu, K. Miyai, S. Hayashizaki, Y. Endo, N. Hata, Y. Tijima, R. Fushimi, Endocrinol. Jpn., 1986, 33, 905.
[4] A.S. Buinovskii, S.A. Bezrukova, N.A. Kolpakova, A.I. Maslyuk, Diagnostika Materialov, 2004, 3, 70.
[5] E. Pungor, R. Hollos, Acta Chim. Acad. Sci. Hung., 1961, 27, 63.
[6] G. Somer, S. Kalaci, G. Ekmekci, Sensors and Actuators B, 2001, 81, 122.